Prevista Dry washbasin element, fixed connections
for WB with single-hole fitting
Year built (from): | 01.03.2019 |
Trade mark rights exist for this document; for further information, go to viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and plumbing experts and trained personnel
Drywall builders
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe and are provided as a support feature.
Scope / Notice | Regulations applicable in Germany |
---|---|
Suitable masonry walls | EN 1996‑1‑1 |
Suitable concrete walls | DIN 1045 |
Suitable stud frames | DIN 18183 |
The Prevista Dry washbasin element is suitable for mounting on masonry wall constructions and stud frames pursuant to the regulations in section Standards and regulations and can be used in a Prevista Dry Plus pre-wall construction.
The washbasin element is compatible with all common washbasin ceramics, even with larger projection (barrier-free).
Drain elbow (outlet side) |
---|
Rubber nipple |
Hole diameter for fixing in wooden frame construction |
Construction height |
DN 40 / 50 |
DN 50 / 30 |
11 mm |
1120 mm |
For mounting, Viega recommends to use the Prevista Dry fixing set.
Prevista Dry fixing set model8570.36 for fixing the Prevista Dry elements in single / line mounting, single mounting directly onto the installation body or corner mounting on masonry or steel stud frame.
Prevista Dry fixing set model 8573 for single mounting of Prevista Dry elements to the solid wall.
Prevista Dry Plus fixing set model 8570.49 for single mounting of the Prevista Dry elements in Prevista Dry Plus.
Masonry walls
Concreted walls
Steel stud frame
Prevista Dry Plus pre-wall constructions
With the construction height, the marked height of the upper edge of the finished floor must be observed.
Masonry and concrete walls
When mounting multiple washbasin elements with an interval of > 500 mm, Viega recommends to use a Prevista Dry support bracket (model 8570.48). Observe the instructions for use of the support bracket when mounting.
For mounting, Viega recommends to use a Prevista Dry fixing set.
Determine and mark the fixing points.
X1: 1100 mm
X2: Depending on the fixing set used
Determine and mark the fixing points on the floor.
X3: 375 mm
Drill the holes.
Insert the dowels.
Mount the Prevista Dry fixing set pursuant to the instructions for use for the fixing set.
Loosen the feet of the element using a fork spanner.
Adjust the construction height of the element in accordance with the on-site marking of the upper edge of the finished floor.
X: 1000 mm
Tighten the feet of the element using a fork spanner.
The element is attached to the wall.
When mounting without a continuous rail above the element, the Prevista Dry Plus fixing set (model 8570.49) must also be used. See example with WC element model 8521.
Mount the Prevista Dry Plus pre-wall construction pursuant to the instructions for use of the Prevista Dry Plus system.
Position the element on the floor rail.
Fix the feet on the floor rail using the clips.
Set the height of the element by means of the feet.
Fix the element with the Prevista Dry Plus rail connectors.
The element is fixed in the Prevista Dry Plus pre-wall construction.
Position the element on the floor rail.
If necessary, adjust the foot depth from 50 mm (pre-mounted) to 75 mm.
Pull the foot out and turn by 90°.
Fix the feet.
Adjust the construction height of the element in accordance with the on-site marking of the upper edge of the finished floor.
X: 1000 mm
Attach the element to the stud frame using the screws supplied.
If applicable, connect further elements to the element via the stud frame.
Mount the drain elbow.
Mount the seal and the plug.
Turn in the threaded rods by hand.
Tighten the nuts of the threaded rods with a fork spanner.
Place the protective caps on the threaded rods.
Make the water connections.
The opening in the support can be used as an alternative bushing for plastic pipelines.
Example with washbasin element model 8535.
Impress a suitable plasterboard cladding panel at the plug using gentle pressure.
Cut out the recesses for the plug and the threaded rods.
X1: min. 58 mm
Clad the element with suitable plasterboard cladding panels and tile it.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.