Urinal Module Siphon Sensor Technology
for urinal with concealed flushing system
Year built (from): | 01.07.2015 |
Trade mark rights exist for this document, further information can be found at viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and sanitary professionals and trained personnel
Drywall builder
It is not permitted for individuals without the abovementioned training or qualification to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns against possible life-threatening injury.
This symbol warns against possible serious injury.
This symbol warns against possible injury.
This symbol warns against possible damage to property.
Notes give you additional helpful tips.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at viega.com/standards .
Scope / Notice | Regulations applicable in Germany |
---|---|
Fulfilled noise protection requirements | DIN 4109 |
Fulfilled noise protection requirements | DIN 4109 (additional sheet 2) |
Fulfilled noise protection requirements | VDI 4100 SSt I-SSt II |
The urinal module is designed for mounting in the urinal element model 8152.4.
The urinal module is compatible with the equipment set "Siphon sensor technology" model 8352.2.
The urinal module complies with the noise insulation requirements specified in section Regulations from section: Sound protection .
The product has the following technical data:
drain elbow |
---|
Fitting connection |
Maximum height of urinal inlet from upper edge of the finished floor |
DN 50 |
Rp ½ |
|
Secure the module onto the open side of the Steptec rail with the slot nuts supplied.
Press the slot nut in gently and secure in the open rail side with a 90° turn.
Tighten slot nut with a fork spanner (SW 17).
Mount drain elbow in mounting bracket.
Secure with a bracket.
Set height of the drain elbow (50 mm).
Mount threaded bolts.
Seal double nipple from one side.
Screw double nipple into the wall plate.
Affix flexible hose onto the double nipple.
Seal supply fitting.
Screw supply fitting into the wall plate.
Connect water line.
Risk of electric shock
Work on the electrics may only be carried out by trained electricians.
Always de-energise the connection line before work is commenced.
Lay the electrical cable in the installation set.
If necessary, align the height of the urinal element.
Observe the ceramic manufacturer's information when aligning the connections.
If necessary, swap the installation set with the mounting bracket and the crossbeam of the threaded bolts with each other.
Clad urinal element (1 x 12.5 mm).
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.