Viega Eco Plus WC element
Viega Eco Plus
Year built (from): | 01.08.2011 |
Trade mark rights exist for this document; for further information, go to viega.com/legal .
The information in this instruction manual is directed at the following groups of people:
Heating and sanitary professionals and trained personnel
Drywall builder
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e. g. EN) and/or in Germany (e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe. National regulations can be found on the relevant web site of your country at viega.com/standards .
Scope / Notice | Regulations applicable in Germany |
---|---|
Fulfilled noise protection requirements | DIN 4109 |
Fulfilled noise protection requirements | DIN 4109 (additional sheet 2) |
Fulfilled noise protection requirements | VDI 4100 SSt I-SSt II |
The Viega Eco Plus WC element is suitable for mounting on masonry wall constructions and stud frames.
The WC element is equipped as follows:
The WC element is compatible with all common WC ceramics, even with larger projection (barrier-free).
The WC element can be extended by the following compatible components:
fixing element (model 8169.2)
The fixing element is suitable for barrier-free installation. Supports and handles can be mounted on the fixing element. The construction height of the fixing element is 1130 mm.
Product |
---|
Standard |
Visign for Style |
Visign for More |
Visign for Care sensitive |
Visign for More sensitive |
Visign for Public |
Name | Model |
---|---|
Flush plate Standard 1 | 8180.1 |
Flush plate Visign for Style 10 | 8315.1 |
Flush plate Visign for Style 11 | 8331.1 |
Flush plate Visign for Style 12 | 8332.1 |
Flush plate Visign for Style 12 | 8332.4 |
Flush plate Visign for Style 13 | 8333.1 |
Flush plate Visign for Style 14 | 8334.1 |
Flush plate Visign for More 100 | 8352.1 |
Flush plate Visign for More 102 | 9353.1 |
Flush plate Visign for More 103 | 8355.1 |
Flush plate Visign for More 104 | 8354.1 |
Flush plate sensitive Visign for Care | 8352.21 |
Flush plate sensitive Visign for More 100 | 230 V 8352.11 |
Flush plate sensitive Visign for More 103 | 230 V 8355.11 |
Flush plate Visign for Public 1 | 8326.1 |
Flush plate Visign for Public 2 | 8327.1 |
Flush plate Visign for Public 5 | 8326.16 |
Flush plate Visign for Public 6 | 8326.15 |
Remote actuation Visign for Public 1 | 8326.21 |
Cover plate Visign for Public | 8326.9 |
Small flush volume |
---|
Large flush volume |
Factory setting | approx. 3 l |
Setting range | approx. 2.5–3 l |
Factory setting | approx. 4.5 l |
Setting range | approx. 4.5–6 l |
The WC element can be mounted on the following walls:
masonry walls
concreted walls
metal support profile
The WC element may only be mounted on even wall surfaces.
With the construction height, the marked height of the upper edge of the finished floor must be observed.
The installation depth can be between 85 mm and 200 mm.
The WC element can only be used in combination with wall-hung WCs (fixing gauges for bore hole 180 mm or 230 mm).
The WC element can be extended by a remote actuation Visign for Public1 (model 8326.21) or by an electronic actuation (model 8350.33), as well as by sensitive flush plates (model 8352.21, 8352.11 and 8355.11). The corresponding actuation method must be prepared before the WC element is clad and tiled.
The corresponding empty pipe (included in the scope of delivery of the remote actuation) is required when preparing the remote actuation Visign for Public1.
The following tools are required for mounting the WC element:
drill with 10 mm drill bit
ratchet with sockets: 13 mm / 17 mm
fork or ring spanner: 13 mm / 17 mm / 19 mm
Masonry and concreted walls
You should use a support bracket (model 8165) when mounting multiple WC elements with an interval of > 490 mm. Observe the instructions for use of the support bracket when mounting.
Determine and mark fixing points.
X1: 390 mm (model 8180.73)
X2: 440 mm (model 8173)
X3: At a construction height of 1130 mm, the size is 1110 mm.
Drill holes.
Mount the fixing set with the fork spanner (size 13).
Align the height (size 17) of the WC element in accordance with the cutting check.
Attach WC element to the floor using the fork spanner (size 13) and the screws and dowels supplied.
Align WC element.
Set the installation depth of the pre-wall element (85–200 mm) with the fork spanner (size 17).
Attach WC element to the wall.
Double-clad WC element with IFGP cladding panels (model 8055.10) (2 x 12.5 mm).
Determine and mark fixing points.
X1: 390 mm (model 8180.73)
X2: 440 mm (model 8173)
X3: 1110 mm.
Drill holes.
Mount the fixing set with the fork spanner (size 17).
Align the height (size 17) of the WC element in accordance with the cutting check.
Attach WC element to the floor using the fork spanner (size 13) and the screws and dowels supplied.
Align WC element.
Set the installation depth of the pre-wall element (130–200 mm) with the fork spanner (size 17).
Attach WC element to the wall.
Double-clad WC element with IFGP cladding panels (model 8055.10) (2 x 12.5 mm).
If necessary, adjust (pre-mounted) foot depth from 75 mm to 50 mm.
Pull the foot out and turn by 90°.
Determine construction height in accordance with the on-site marking of the upper edge of the finished floor.
Pull WC element up (cutting check) and align.
Mark holes for floor supports and drill.
Tighten feet with the fork spanner (size 17).
Attach WC element to the stud frame using the screws supplied.
Optional:
Viega Eco Plus fixing element model 8169.2.
Double-clad WC element with IFGP cladding panels (model 8055.10) (2 x 12.5 mm).
The corresponding empty pipe (included in the scope of delivery of the remote actuation) is required when preparing the remote actuation Visign for Public1 (model 8326.21).
Lead the empty pipe from the hollow wall socket into the concealed cistern.
Distance from the remote actuation to the cistern (x)
min. 1.0 m
max. 1.7 m
Lead empty pipe from the switch or button into the concealed cistern, to connect the concealed socket and concealed cistern.
Positioning of the cistern power pack
X1= max. 0.75 m
X2= max. 2.75 m with an extension cable, 1 x article number 628 505
X3= max. 4.75 m with two extension cables, 2 x article number 628 505
Immediate re-flushing of the flush volume is possible at the factory settings.
The WC element is factory-set at a small flush of approx. 3 l. The small flush volume can be set from approx. 3 l to approx 2.5 l.
Remove the drain valve from the concealed cistern.
Push the slide control on the side of the overflow pipe to the desired small flush volume:
Top position: approx. 2.5 l
Bottom position: approx. 3 l
The WC element is factory-set at a large flush volume of approx. 4.5 l. The large flush volume can be set to approx. 6 l.
Remove the drain valve from the concealed cistern.
Push the slide control below the drain valve to the desired large flush volume:
left: approx. 4.5 l
right: approx. 6 l
Remove cover.
Loosen locking device the mechanism.
Remove bow of the mechanism from the drain valve.
Remove mechanism out the front.
Push the holder of the restrainer together.
Remove restrainer upwards.
Remove the restrainer towards the front.
Close open corner valve.
Separate the flexible hose from the corner valve at the union nut (SW 19).
Release the filling valve holder from the bracket.
Remove filling valve from the revision opening in a horizontal position.
Cleaning may only be carried out by specialist trade professionals or qualified experts.
The concealed cistern is constantly under mechanical, chemical, and physical stress. For this reason, the components must be cleaned as required, and the drain and filling valve seals renewed.
In areas or regions with hard water due to high concentration of calcium or magnesium salts, there is the risk of limescale deposits developing on the inlet and drain valves. The valves may have to be replaced, depending on the extent of the deposits.
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.