Concealed pipe interrupter
for Multiplex Trio, Rotaplex Trio
Year built (from): | 02.02.1998 |
The information in this instruction manual is directed at the following groups of people:
Heating and plumbing experts and trained personnel
Operators
Consumers
Individuals without the abovementioned training or qualification are not permitted to mount, install and, if required, maintain this product. This restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use.
Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs.
This symbol warns of possible life-threatening injury.
This symbol warns of possible serious injury.
This symbol warns of possible injury.
This symbol warns of possible damage to property.
This symbol gives additional information and hints.
This instruction for use contains important information about the choice of product or system, assembly and commissioning as well as intended use and, if required, maintenance measures. The information about the products, their properties and application technology are based on the current standards in Europe (e.g. EN) and/or in Germany (e.g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/Germany. These should serve as recommendations in the absence of corresponding national regulations. The relevant national laws, standards, regulations, directives and other technical provisions take priority over the German/European directives specified in this manual: The information herein is not binding for other countries and regions; as said above, they should be understood as a recommendation.
The following standards and regulations apply to Germany / Europe and are provided as a support feature.
Scope / Notice | Regulations applicable in Germany |
---|---|
Provided that the installation was carried out in compliance with the instructions in section Potable water connection , the concealed pipe interrupter meets the requirements defined in the standards. | EN 1717 |
The concealed pipe interrupter model (6161.81) is suitable for Multiplex Trio drain and overflow fittings and Rotaplex Trio drain and overflow fittings.
A suitable rosette Visign RU2 (model 6161.89) is not included in the scope of delivery and must be purchased separately.
The concealed pipe interrupter must be connected to pipes and lines suitable for potable water. 3/4 inch adapters are suitable for connection; Viega plug-in seat connection screw fittings are also compatible (e.g. Viega plug-in seat Sanfix P connection screw fitting model 2119 or Raxofix connection screw fitting model 5329). Euro cone connection screw fittings are not compatible.
To prevent the intrusion of non-potable water into the potable water pipelines, concealed pipe interrupters are installed between the mixer tap and an inlet. The concealed pipe interrupters can be used as a safeguarding device if the following points are ensured during installation:
The direction of flow runs from diagonally downward to vertically downwards. Pipelines are not allowed to rise downstream from the pipe interrupter.
The pipe interrupter must be installed at least 150 mm above the highest possible non-potable water level.
There must not be any shut-off downstream from the pipe interrupter.
The pipe interrupter must not be involved in the pressure test with an installed membrane, the membrane is destroyed during a pressure test and the pipe interrupter cannot perform its function. If a pressure test is required, the insert with the membrane must be exchanged for a connecting piece (model 6161.83).
Pipe interrupters may only be used with compatible components.
For the applicable directives, see Regulations from section: Potable water protection .
Dimensions |
---|
Thread size |
¾ inch |
The rosette must be purchased separately and fitted on the top stem to complete the mounting of the pipe interrupter.
The rosette Visign RU2 (model 6161.89) is suitable for the top stem of the concealed pipe interrupter.
If a pressure test is required, the insert with the membrane must be exchanged for the connecting piece shown here (model 6161.83).
Two screws are required for the fixing of the concealed pipe interrupter.
3/4 inch adapters are suitable for connecting the concealed pipe interrupter to pipes; Viega plug-in seat connection screw fittings are also compatible. Euro cone connections are not compatible.
The plug-in seat connection Sanfix P (model 2119) is suitable for the concealed pipe interrupter.
The plug-in seat connection Raxofix (model 5329) is suitable for the concealed pipe interrupter.
The following requirements exist for the mounting of a pipe interrupter:
The pipe and line, in which the pipe interrupter is installed, are suitable for the supply of potable water.
The tub fitting has been installed and the connection lines are accessible.
fine-toothed saw
water pump pliers
The following material must be available during mounting:
Concealed pipe interrupter
if applicable, fixing material and connection screw fittings Required accessories
rosette Required accessories
Ensure that the pipe interrupter is mounted at least 150 mm above the highest possible non-potable water level.
Note that the flow direction must run from diagonal to vertical downwards.
Make sure that the line does not continue to rise downstream from the pipe interrupter.
Make sure that you have the required accessories (rosette, connection sets) to be able to carry out the mounting completely.
Make sure that the protective plug is still on the top stem during assembly.
Depending on the type of installation, the connection of the mixing tap and the pipe interrupter can made with metal pipes and a press connection or with plastic pipes.
Connection example with Viega connection set (model 6161.86)
Seal the adapter elbow and twist it into the connection of the mixer tap.
Push the union nut and the clamping ring onto the water carrying pipe.
Push the pipe onto the support body of the adapter elbow as far as it will go and screw it together with the union nut.
Install the top stem.
Ensure that the sealing element is correctly in place.
Insert the protective plug.
To ensure the proper functioning of the pipe interrupter, the protective plug must be removed before commissioning.
Push the union nut and the clamping ring onto the water carrying pipe.
Push the narrow end of the screw fitting into the pipe as far as it will go.
Push the free end of the screw fitting into the connection of the pipe interrupter.
Screw the connection together.
Euro cone connections are not compatible.
Adjust the pipe interrupter.
Pay attention to the correct flow direction (direction of arrow, from top to bottom).
Mark the drill holes.
Drill the holes.
Screw the pipe interrupter tight with two screws (SW 4.5 up to 5).
Grout the pipe interrupter and the connection lines.
Integrate the pipe interrupter with mounted sealing collar into the bonded sealing.
Then tile the wall.
If the shaft top is too long:
Remove the protective plugs.
Shorten the shaft top with a fine-toothed saw. Take care to shorten to the proper length. The shaft top must be flush with the height of the tiles.
If impurities have managed to enter the shaft top during the work, the clean the shaft top.
If the shaft top has not been shortened and it is ensured that no more contamination can enter the shaft top:
Remove the protective plug.
Hold the rosette with the open side facing downwards.
Mount the rosette on the shaft top.
To connect the bathtub inlet:
Push the union nut and the clamping ring onto the water carrying pipe.
Push the narrow end of the screw fitting into the pipe as far as it will go.
Push the free end of the screw fitting into the connection elbow.
Use the union nut to screw the pipe tight at the connection elbow.
Euro cone connections are not compatible.
Insert the connection elbow into the overflow unit. The connection elbow must latch into the overflow unit with a noticeable clicking sound.
If a pressure test is required, the insert with the membrane must be exchanged for a connecting piece, model 6161.83. The pressure test should be carried out before connecting the drain set.
Check for visible leaks.
Product damage due incorrect maintenance
Limescale deposits can destroy or be detrimental to the functioning of the membrane in the pipe interrupter insert and must therefore be removed. If the insert and the membrane in the pipe interrupter are either not or incorrectly cleaned, then the product's functionality may be restricted or destroyed. Non-potable water can contaminate the potable water.
To ensure the constant functionality of the pipe interrupter:
The limescale deposits must be removed regularly by qualified personnel.
In the case of extensive limescale deposits, have the insert and the membrane replaced by trade professionals.
Remove rosette.
Grip and pull the insert out of the casing using multigrip pliers horizontally.
Carefully rinse the insert.
Use a new insert (model 6161.82).
Hold the cleaned or new insert with multigrip pliers and insert into the casing of the pipe interrupter from the front.
Pay attention to the correct flow direction (direction of arrow, from top to bottom).
Re-mount the rosette.
The rosette can be cleaned by every user, if necessary. The rosette may only be cleaned using mild cleaning agents containing soap and a soft cloth.
Scouring milk and cleaning agents or disinfectants containing the following ingredients may not be used:
alcohol
Ammoniac
hydrochloric acid
phosphoric acid
acetic acid
Separate the product and packaging materials (e. g. paper, metal, plastic or non-ferrous metals) and dispose of in accordance with valid national legal requirements.